Light flexible tubes for electrical installations, TI LSC 2221

2019-07-16T22:56:45+02:00
– Usage: laying in concrete
– In accordance to EN 61386-1: 2008 EN 61386-22: 2004 + A11: 2010
– Pressure resistance: 320N/5cm³ at 20° C
– Temperature range of application -5° C to 60° C
– Non-flammable (T <750° C) according to EN 60695-2-10

Inner diameter (mm) Outer diameter (mm) Code Packaging (m)
11 16 000091 50
13,5 18,5 000092 50
16 20 000094 50
20 25 000093 50
26 32 000095 25
30 36 000106 25
36 42 000102 20
48 54 000107 20

 

Light flexible tubes for electrical installations, TI LSC 22212019-07-16T22:56:45+02:00

Very light flexible tubes for electrical installations, TI VLSC 1121

2019-07-16T22:53:31+02:00
– Usage: plastering
– In accordance to EN 61386-1: 2008 EN 61386-22: 2004 + A11: 2010
– Resistance to pressure: 125N/5cm³ at 20° C
– Temperature range of application -5° C to 60° C
– Non-flammable (T <750° C) according to EN 60695-2-10

Inner diameter (mm) Outer diameter (mm) Code Packaging (m)
11 16 000104 50
13,5 18,5 000100 50
16 20 000101 50
20 25 000108 50
26 32 000103 25

 

Very light flexible tubes for electrical installations, TI VLSC 11212019-07-16T22:53:31+02:00

Extensions for flexible ribbed tubes

2019-07-16T22:49:47+02:00
– Designed for setting up lightweight and very light flexible tubes
– In accordance with EN 61386-1: 2008; EN 61386-25: 2011

For tubes with outer/inner diameter Code Packaging (piece)
18,5/13,5 000154 20
20/16 000155 20
25/20 000156 20

 

Extensions for flexible ribbed tubes2019-07-16T22:49:47+02:00

Clamps for flexible tubes

2019-07-16T22:45:14+02:00

– Usage: to fix flexible tubes in the wall or on the floor
– In accordance with EN 61386-1: 2008; EN 61386-25: 2011

One-row clamps

Name Dimensions φ Code Packaging
TI OR 13,5 13,5 000132 50
TI OR 16 16 000122 50
TI OR 23 23 000123 50
TI OR 26 26 000124 50

 

Two-row clamps

Name Dimensions φ Code Packaging
TI OR 13,5 13,5 000125 50
TI OR 16 16 000126 50
TI OR 23 23 000127 50
TI OR 26 26 000128 50

 

Clamps for flexible tubes2019-07-16T22:45:14+02:00

Light-weight self-extinguishing flexible tubes for electric installations TI VLSC 1121203

2019-07-16T17:04:14+02:00
Execution TI VLSC 1121 … 1 Code Outer diameter Inner diameter Packaging (m)
d16 000087 16 11 50
d18,5 000088 18,5 13 50
d20 000109 20 16 50
d25 000079 25 20 50
d32 000089 32 26 25

 

Use: for electrical installations – wall mounting, gypsum boards, in buildings made of wood;
Material: the material is temperature resistant, polypropylene, co-polymer that is self-extinguishing
Color: grey

Physical features:
– resistance to pressure 125 N/5cm² at 20ºC
– temperature application from -5ºC to 90ºC
– self-extinguishing V0

Light-weight self-extinguishing flexible tubes for electric installations TI VLSC 11212032019-07-16T17:04:14+02:00

Halogen Free very light self-extinguishing flexible tubes for electrical installations TI HF VLSC 112220301310

2019-07-15T23:42:42+02:00

 

Performance TI VLSC 1122……1 Code Outer diameter Inner diameter Packaging
d16 000056 16 11 50
d20 000057 20 16 50
d25 000058 25 20 50
d32 000059 32 26 25

 

Usage: for electrical installations for wall mounting in public buildings, hospitals, shopping malls
Material: they are made of halogen-free material
Color: gray
Physical characteristics:
– Resistance to pressure 125 N / 5 cm² at 20ºC
– temperature application -5 ºC to 90 ºC
– self-extinguishing V1

Halogen Free very light self-extinguishing flexible tubes for electrical installations TI HF VLSC 1122203013102019-07-15T23:42:42+02:00