Pozovite nas: +387 51 392 311 Fax: +387 51 394 155|tehno-inde@blic.net

ZunA

About ZunA

This author has not yet filled in any details.
So far ZunA has created 297 blog entries.

Gal shield

2019-07-16T09:48:41+02:00

– In accordance with EN 60060-3, EN 60695-10-2, EN 60695-2-10
– Submissive voltage 10kV
– Inflammable (T<750°C) according to EN 60695-2-10
– Temperature stability of 70°C

Name Code Packaging
Gal shield 50/1 000120 5000

 

Gal shield2019-07-16T09:48:41+02:00

Plastic cups

2019-07-16T09:38:55+02:00

They are made of PC polycarbonate, which is resistant to impact. Material is tough, and at the same time transparent as glass.

Usage: they are used on public places, concerts, swimming pools and all other places where the use of glass is not allowed due to possible injuries.

Name Volume Packaging Code
Brandy cup 4 cl 100  

 

Name Volume Packaging Code
Cocktail cup 3 dl 132  

 

Plastic cups2019-07-16T09:38:55+02:00

Linear water drainage systems with zinc and plastic grille

2019-07-17T19:11:46+02:00

Weight capacity: A15 in accordance with EN 1433:2002

Code Name Height Width Length Weight unit Packaging
000011 Water drain (black/gray) 99.8 123.4 500 607 piece 32
000010 Channel grille 130×500 black/gray 32 122.5 500 617 piece 32
000009 Zinc grille 1000 mm 20 122.5 1000 1623 piece 10
000012 Plug for channel adapter (diameter 50/63/75)       65 piece 10

 

Usage: for the drainage of atmospheric waters at pedestrian crossings, bicycle trails, green areas, parks, gardens, city squares, parking for own vehicles, car accesses, swimming pools, dressing rooms, etc.

The drain is made of polyamide which gives it high resistance to high temperatures and thrust forces. The grids are made in two variants:
1. Plastic grid made of PA and
2. The grid made of galvanized steel sheets, 1.25 thick

The channel plug has holes (drains) to which pipe with diameter of 50/63/75 can be fitted. Also, depending on the need, the drain pipe connection can also be installed on the bottom side of the channel.

The drains can be easy attached to one another. It allows setting to the desired length. It is mounted on a straight line excavation in a ground, that is then concreted.

INSTALLATION INSTRUCTIONS
The opening in which the channel is laid must have enough space for the channel, drainage pipes, as well as for the concrete base (H) and the walls (S)
The measures to be followed are given in the table:

CLASS EN 1433   A15
WEIGHT CAPACITY IN THE CLASS 1433 KN 15
Minimum height of concrete base (H) mm 100
Minimum thickness of the side wall (S) mm 100

 

It is necessary that the concrete base be slightly sloped to drain water. In the case of frequent transitions of freight vehicles, it is recommended that the concrete base be reinforced with the iron reinforcement net.

Prior to the filling of concrete, it is necessary to set up and connect all the channels to avoid the possible asymmetry of the drainage line.

The filling height of the concrete is determined according to the thickness of the final layer. It is necessary that the finishing layer be 3-5 mm higher than the height of the grid. Before filling the concrete, it is necessary to set the grids and fix the hooks to avoid deformation of the channel and the entire drainage line.

Linear water drainage systems with zinc and plastic grille2019-07-17T19:11:46+02:00

Halogen Free very light self-extinguishing flexible tubes for electrical installations TI HF VLSC 112220301310

2019-07-15T23:42:42+02:00

 

Performance TI VLSC 1122……1 Code Outer diameter Inner diameter Packaging
d16 000056 16 11 50
d20 000057 20 16 50
d25 000058 25 20 50
d32 000059 32 26 25

 

Usage: for electrical installations for wall mounting in public buildings, hospitals, shopping malls
Material: they are made of halogen-free material
Color: gray
Physical characteristics:
– Resistance to pressure 125 N / 5 cm² at 20ºC
– temperature application -5 ºC to 90 ºC
– self-extinguishing V1

Halogen Free very light self-extinguishing flexible tubes for electrical installations TI HF VLSC 1122203013102019-07-15T23:42:42+02:00

Halogen free stiffed protective tubes for electrical installations TI HF PN HF2222

2019-07-15T23:43:51+02:00

In accordance with EN 61386-1:2008; EN 61386-21:2004+A11:2010; 50267-2-1/-2-2

 

Performance TI HF PN 2222 Code Outer diameter Inner diameter Packaging
D-12 000170 12 10.5 30
D-15 000171 15 13.5 30
D-18 000172 18 16 30
D-25 000173 25 23 30
D-32 000174 32 29 30

 

Physical characteristics: they are made of materials with halogen free characteristics
Resistance to pressure: 320N/5 cm²
Temperature range of application: from -5⁰C to 90⁰C
Length of tube: 3 m
Color: white

Halogen free stiffed protective tubes for electrical installations TI HF PN HF22222019-07-15T23:43:51+02:00

Accessories for halogen Free rigid protective tubes for electrical installations TI HF PN HF2222

2019-07-11T00:08:31+02:00

In accordance with EN 61386-1:2008; EN 61386-21:2004+A11:2010; 50267-2-1/-2-2

Halogen Free clamps for rigid tubes for electrical installations

 

Performance Code Packaging
TI OPN HF D12/10,5 000163 100
TI OPN HF D15/13,5 000164 100
TI OPN HF D18/16 000165 100
TI OPN HF D25/23 000166 100
TI OPN HF D32/29 000167 100

 

Material: They are made from materials with halogen free characteristics 
Color: white

Halogen free attachments for rigid tubes for electrical installations

 

Performance Code Packaging
TI NPN HF D12/10,5 000158 100
TI NPN HF D15/13,5 000159 100
TI NPN HF D18/16 000160 100
TI NPN HF D25/23 000161 100
TI NPN HF D32/29 000162 100

 

Material: They are made from materials with halogen free characteristics 
Color: white

Accessories for halogen Free rigid protective tubes for electrical installations TI HF PN HF22222019-07-11T00:08:31+02:00

PVC poles for tomatoes, beans, peppers

2019-07-10T23:47:34+02:00

 

 

Material: hard PVC
Length: 2m or per request
Code: 001030
Use: for growing tomatoes, cucumbers, beans, flowers etc.

The poles are designed with anti-slip plumelet and reinforcements that allow attachment of a single plant to pole and forming of row breeding by connecting of poles in usual way. On the pole there is a pointed pin that makes it easy to pour into the ground.

If necessary, it is possible to drill a hole at a certain height for a drop-by-drop watering system. This way of planting and growing the climbing plant increases the yield of 20-30%.

Engravings with plumelet, which are also reinforcements, prevent slipping of the binding material.

They are made in lengths of 2m. The outer diameter is 26mm, and the length can be adjusted to the needs of customers.

PVC poles for tomatoes, beans, peppers2019-07-10T23:47:34+02:00

Connection accessories

2019-07-10T23:22:25+02:00

In accordance with IEC 60884-1

Name Code Packaging
Cable plug – rubberized two-pole 16A/250V – black 000077 1
Cable plug – rubberized two-pole 16A/250V – white 000007 1
Name Code Packaging
Portable socket on cable-clutch 16A/250V   1

Connection accessories2019-07-10T23:22:25+02:00

Connection cables

2019-07-10T23:10:03+02:00

In accordance with IEC 60884-1

Name Cable type Length Code
Connection cable 16A 250V 3500W white H05VV-F 3G1.5 (PP/J-Y 3×1.5) L-1.5 m 001001
Connection cable 16A 250V 3500W white H05VV-F 3G1.5 (PP/J-Y 3×1.5) L-2 m 001002
Connection cable 16A 250V 3500W white H05VV-F 3G1.5 (PP/J-Y 3×1.5) L-3 m 001003
Connection cable 16A 250V 3500W black H05VV-F 3G1.5 (PP/J-Y 3×1.5) L-1.5 m 001008
Connection cable 16A 250V 3500W black H05VV-F 3G1.5 (PP/J-Y 3×1.5) L-2 m 001010
Connection cable 16A 250V 3500W black H05VV-F 3G1.5 (PP/J-Y 3×1.5) L-3 m 001012
Connection cable 16A 250V 3500W white H05VV-F 3G2.5 (PP/J-Y 3×2.5) L-1.5 m 001004
Connection cable 16A 250V 3500W white H05VV-F 3G2.5 (PP/J-Y 3×2.5) L-2 m 001005
Connection cable 16A 250V 3500W white H05VV-F 3G2.5 (PP/J-Y 3×2.5) L-3 m 001006
Connection cable 16A 250V 3500W black H05VV-F 3G2.5 (PP/J-Y 3×2.5) L-1.5 m 001009
Connection cable 16A 250V 3500W black H05VV-F 3G2.5 (PP/J-Y 3×2.5) L-2 m 001011
Connection cable 16A 250V 3500W black H05VV-F 3G2.5 (PP/J-Y 3×2.5) L-3 m 001013

 

Connection cables2019-07-10T23:10:03+02:00

Connection three-phase cables

2019-07-10T23:05:10+02:00

In accordance with 60884-1

Name Cable type Length Code
Connection cable three-phase 16A 400V 10000W white H05VV-F 5G2.5 (PP/J-Y 5×2.5) L-1.5 m 001014
Connection cable three-phase 16A 400V 10000W white H05VV-F 5G2.5 (PP/J-Y 5×2.5) L-2 m 001015
Connection cable three-phase 16A 400V 10000W white H05VV-F 5G2.5 (PP/J-Y 5×2.5) L-3 m 001016
Connection cable three-phase 16A 400V 10000W black H05VV-F 5G2.5 (PP/J-Y 5×2.5) L-1.5 m 001017
Connection cable three-phase 16A 400V 10000W black H05VV-F 5G2.5 (PP/J-Y 5×2.5) L-2 m 001018
Connection cable three-phase 16A 400V 10000W black H05VV-F 5G2.5 (PP/J-Y 5×2.5) L-3 m 001019

 

Connection three-phase cables2019-07-10T23:05:10+02:00
Go to Top